Waters Alliance e2695 HPLC Separation Module

The Waters Alliance e2695 HPLC Separation Module is equipped with an integrated binary gradient pump for efficient solvent delivery and an advanced multisample injector for precise sample preparation and injection.

Original price was: $19,999.00.Current price is: $12,999.00.

SKU:Waters Alliance e2695

Waters Alliance e2695 Separations Module is a high-performance liquid chromatographic system with a quaternary, low-pressure mixing pump and inline vacuum degassing. Flow rates from 50 uL/min to 5 mL/min can be generated for use with 2.1 mm ID columns and larger.

  • Time-tested, dependable, and robust workhorse for your HPLC separations
  • Integrated solvent and sample management with consistent system-to-system performance and high reproducibility
  • Simplify your daily LC system start-up with advanced software functionality

The autosampler has a maximum capacity of 120 vials (12×32, 2-mL) with programmable temperature control from 4 to 40°C. A heated column compartment provides temperatures from 5 degrees above ambient to 65°C. The detector is a photodiode array (model 2996) with a wavelength range of 190-800 nm and sensitivity settings from 0.0001-2.0000 absorbance units.

 

Waters Alliance e2695 Features and benefits

  • Quaternary solvent blending. Support isocratic and gradient applications with 11 unique gradient profile curves and blend up to 4 solvents in any proportion with Auto-Blend Technology. Compatible with solvent types such as reversed-phase, normal-phase, GPC, SEC, and IEX.
  • Advanced solvent delivery capabilities. Serial flow path with pulse-free solvent delivery without the use of dampeners. Online solvent degassing and automated solvent compressibility compensation for accurate flow. Integrated seal wash for robust operation with all solvent types is standard.
  • Optional, temperature-controlled environment. House up to 120 vials in an optional, temperature-controlled environment. Achieve low carryover with active and user-programmable needle wash. Variable injection volumes from 0.1 to 100 μL standard and up to 2 mL optional. Support STAT samples and auto-addition.
  • Detection and column options. Get optional column heating, heating/cooling, or column switching capabilities. Detection capabilities include photodiode array, UV/Vis, fluorescence (FLR), refractive index (RI), evaporative light scattering (ELS), electrochemical, conductivity, and mass detection.
  • Intuitive interface and software. Get instant access to system settings through the large LCD screen with simplified daily set-up with SystemPREP. Supports Empower, MassLynx, and 3rd party software packages.
  • Compliance-ready. Supports Waters Empower-based automated system qualification tool (SQT), minimizing the time and cost of annual qualification with standards like GMP, GLP, ISO 17025, and USP <1058>

The e2695 Separations Module has integrated solvent and sample management and includes both a sample heater/cooler and a column heater. The system features quaternary solvent delivery and sample introduction via a direct inject sample manager. The system may be configured for a broad range of applications supported by HPLC optical detectors and mass detectors, with a choice of instrument control and data management software.

The Waters™ e2695 Separations Module, with its integrated solvent and sample management capabilities, provides the flexibility and ruggedness needed to accommodate an enormous range of HPLC System separation challenges.

Include:

  • Waters Alliance e2695 HPLC Separation Module
  • Waters 2487 Dual Wavelength Absorbance Detector/2489 UV/Visible Detector
  • Waters Column Heater
  • Alliance HT Qualification Standards Kit
  • Alliance with Fluorescence Qualification Standards Test Kit
  • Alliance with RI Detector Qualification Standards Kit
  • Alliance Solvent Manager Service Kit
  • Waters 2690 2695 Alliance Performance Maintenance Kit
  • Waters Alliance e2695 Startup Kit with Carousels
  • User Documentation
  • All the necessary cables and tubes.
  • A 1-year warranty is included. Shipping and handling is free!
  • PC DELL Computer w/ Empower 3 FR5 Software (with many software options)
  • LCD Computer Monitors or printers are included

Reference

 

Specifications:
Number of solventsOne to four
Solvent ConditioningVacuum degas, two operating modes, four chambers, <500µL internal volume per chamber
Flow Rate Range0.000 to 10.000 mL/min (0.050 to 5.000 mL/min typical) in 0.001 mL/min increments
Compressibility CompensationAutomatic and continuous
System Delay Volume<650µL, independent of backpressure at 1 mL/min
Plunger Seal WashIntegral, active, programmable
Gradient Profiles11 gradient curves (including linear, step, concave, and convex)
Dry Prime/Wet PrimeAutomatic front panel control, SystemPREP function for automatic solvent(s) purge
Flow RampingTime (0.01 to 30.00 min in 0.01 min increments) to reach maximum flow rate
Maximum Operating Pressure5000 psi (345 bar) (0.010 to 3.000 mL/min) programmable upper and lower limits
Composition Range0.0% to 100.0%, in 0.1% increments
Composition Accuracy± 0.5% absolute, independent of backpressure
Composition Precision≤ 0.15% RSD or ≤ 0.02 min SD, whichever is greater, based on retention time
Flow Precision≤0.075% RSD or ≤0.02 min SD, six replicates, based on retention time or volumetric measures, (0.200 to 5.000 mL/min), isocratic premix
Flow Accuracy±1% or 10µL/min, whichever is greater, 0.200 to 5.000 mL/min, (degassed methanol, at 600 psi backpressure)
Number of Sample Vials120 vials, configured in five carousels of 24 vials each
Number of Sample Injections1 to 99 injections per sample vial
Sample Delivery PrecisionTypically < 0.5% RSD, 5 to 80 µL
Sample Carryover≤ 0.01% for caffeine, under specified conditions
Injection Needle WashIntegral, active, programmable
Injection Accuracy±1µL (± 2%) (50 µL, N=6)
Standard Sample Vial2 mL
Advanced OperationsPriority samplesAuto additionsAuto standards
Injection Volume Range0.1 to 100.0 µL, standard; 0.1 to 2000.0 µL, with optional sample loop
Injector Linearity>0.999 coefficient of deviation (1.000 to 100.000µL)
Minimum Sample Required10µL, using low volume inserts
Dimensions18" W x 22.5" D x 22.5" H (45.7 x 57.1 x 57.1 cm)
Weight100 lbs. (45.5 kg)
Power950 VA (maximum)

Reviews

There are no reviews yet.

Write a review

Bestsellers

Waters Alliance e2695 HPLC Separation Module

Original price was: $19,999.00.Current price is: $12,999.00.
(0 Reviews)
The Waters Alliance e2695 HPLC Separation Module is equipped with an integrated binary gradient pump for efficient solvent delivery and an advanced multisample injector for precise sample preparation and injection.

Olympus EVIS X1 CV-1500 Endoscope Video Processors

Original price was: $39,999.00.Current price is: $29,999.00.
(0 Reviews)
Explore Olympus EVIS X1 CV-1500: A revolutionary endoscopy system combining advanced imaging with enhanced diagnostic features for improved clinical outcomes. Compact, user-friendly design.
Back to Top
Product has been added to your cart